GNSMOTION moves forward without interruption
PTC Lift Column

We effort to product goods with customer satisfaction.

  • ¡¤ Slim design & rugged reliability
  • ¡¤ Fast & Quiet movement
  • ¡¤ Self design & manufacture
specification
CODE FORCE(N) SELF
LOCKING
FORCE(N)
(PUSH)
Typical
Current
at Rated
Load(A)
Typeical Speed at
Rated Load(mm/s)
Stroke
(mm)
Duty
Cycle(min)
on/
off(Int.)
PUSH PULL MAX 24VDC
A 3,500 2,000 3,500 3.2 3.0 150~700 1/9
B 2,500 2,000 2,500 2.8 5.2
C 2,000 2,000 1,000 3.0 6.9
D 1,500 1,500 500 4.0 10.8
E 1,000 1,000 800 1.8 6.1
F 800 800 200 3.2 17.0
G 500 500 300 1.8 14.5

¡Ø The contents are commonly used, please contact us about detailed information

Technical Sheet

Bending Moment

100kgf · m(On MAX.stroke)

Retracted Height

Stroke + 180mm (±α)

Stroke

150 ~ 700mm (General type)

Rated Voltage

24V DC

Weight

12~15kg

IP Protection

IP 42, 54, 66

Material

Anodizing Aluminum

Color

Metalic Silver

Duty Cycle

10% (2/18 min.)

  • Go Top